logo
banner

Marvair AVHA60HPD 5.0 Ton Heat Pump

MarvAir Wall Mounted HVAC Unit
  • High Efficiency
  • 460/60/3
  • Capacity: 5 Ton
  • Voltage: 460V, 3ø,
  • Cert. EER: 10
  • Cert. COP: 3
  • Compressor Type: Scroll
  • Shipping Weight: 530
  • $1 Base List Price

Configure your AVHA60HPD


Unit Options

Electric Heat
000 No Heat [Add $0.00]
060 6kW Electric Heat Strip [Add $560.00]
090 9kW Electric Heat Strip [Add $560.00]
120 12kW Electric Heat Strip [Add $560.00]
120 12kW Electric Heat Strip with Reheat Dehumidification [Add $692.00]
150 15kW Electric Heat Strip [Add $560.00]
Economization
N No Economizer - Manual Damper [Add $0.00]
C Factory Installed Enthalpy Economizer [Add $1159.00]
Special Options
E Extreme Duty: units operate from 0°F to 130°F (-18°C to 54°C). Units with an economizer will operate from -40°F to 130°F (-40°C to 54°C). [Add $1881.00]
D Desert Duty - allows operation in ambient temperatures up 130°F (54°C) in a closed loop design. Also includes thermal expansion valve, sealed condenser fan motor and sealed electrical control panel. [Add $885.00]
R Electric Reheat Dehumidification - Units with reheat require a thermostat and a dehumidistat for proper operation. [Add $0.00]
G Hot Gas Reheat Dehumidification - Units with reheat require a thermostat and a dehumidistat for proper operation. [Add $1562.00]
U Scroll Compressor [Add $0.00]
Ventilation
B Manual Damper (Standard) [Add $382.00]
H Motorized Damper [Add $2899.00]
Y GreenWheel ERV [Add $168.00]
Z Damper (manual) [Add $167.00]
B GreenCube ERV [Add $312.00]
Color
100 Beige [Add $0.00]
200 Gray [Add $89.00]
300 Brown [Add $199.00]
400 White [Add $410.00]
500 Stainless Skin [Add $2627.00]
600 Dark Bronze [Add $337.00]
Variation
HSK Hard Start Kit - Gives compressor higher starting torque under low voltage conditions. [Add $23.56]
DF Dirty Filter Indicator [Add $198.00]
WF Washable Filter - Spun Aluminum construction allows cleaning of filters with water. [Add $160.00]
C1 Protective Condenser Coil Coating - For harsh conditions, e.g., power plants, paper mills or sites where the unit will be exposed to salt water, the condenser coil should be coated. Note: Cooling capacity may be reduced by up to 5% on units with coated co [Add $1485.00]
E1 Protective Evaporator Coil Coating - Where indoor coil is exposed to corrosive air, it may be coated. Note: Cooling capacity may be reduced by up to 5% on units with coated coils. [Add $1161.00]
CE1 Coastal Environmental Package - Recommended for units to be installed near a seacoast. Includes corrosion resistant fasteners, a sealed or partial sealed condenser fan motor, protective coating applied to all exposed internal copper and metal in the conde [Add $3475.00]
CA1 Coat-all Protective Coating - Includes all of the items and coatings in the Coastal Package and, in addition, includes a protective coating on the evaporator coil and a protective coating on all exterior and interior components and sheet metal. [Add $6217.00]
BOX Shipping Crate [Add $937.50]
SJ Compressor Sound Jacket - An insulated jacket reduces the sound of the compressor. [Add $54.00]
LN Low Noise Blower Kits (Field Installed) - Reduces the sound level by up to 6dbA [Add $5600.00]
T1 Coil Cop T1 - Stainless steel channels to secure both the condenser and evaporator coils, warning labels, a speaker, tamper resistant fasteners, loss of charge switch, tri-axis accelerometer and operator panel with status lights. [Add $1707.00]
T2 Coil Cop T2 - Stainless steel channels to secure the condenser coil, warning labels, a speaker, tamper resistant fasteners, loss of charge switch, tri-axis accelerometer and operator panel with status lights. Variation T2 does not include stainless steel [Add $695.00]
OT Outdoor Thermostat [Add $249.00]
MR Modulation Reheat Variation - Maintains a constant discharge temperature during reheat operation. This temperature can be adjusted after installation. [Add $1373.00]
EMS EMS Relay - Provides immediate heat pump or AC shut down when a signal is supplied from a EMS. EMS relay coil is available in 24 VAC, 120 VAC, and 240 VAC. Voltage must be specified [Add $40.00]
LAC Low ambient cooling for operation to 20ºF [Add $54.00]

Unit Accessories

Controls & Controls Accessories
50218 Digital Thermostat non-programmable, 1 stage cool and 1 stage heat. Auto-changeover. For use with single stage compressors ONLY. [Add $113.00]
50123 Digital Thermostat 1 stage heat, 1 stage cool. 7 day programmable. Fan switch: Auto & On. Auto- changeover. Keypad lockout. Non-volatile program memory. Title 24 compliant - no batteries needed. For use with single stage compressors ONLY. [Add $142.00]
50252 Digital Thermostat Non-programmable digital thermostat with backlit display. 2 stage heat and 2-stage cooling. Auto changeover. [Add $184.00]
50107 Digital Thermostat 2 stage heat, 2 stage cool. 7 day programmable. Fan switch: Auto & On. Auto-change over. Status LED’s. Backlit display. Programmable fan. Non-volatile program memory. [Add $213.00]
50254 Dehumidistat Programmable dehumidistat and ventilation controller. Permanent memory retention of set points.Humidity sensor can be field calibrated. High & low dehumidification set points. Outdoor temperature and humidity sensor included. °F or °C selectable. [Add $280.00]
50092 Thermostat guard for use with the 50123 and 50107 thermostats. [Add $60.00]
S/07529 Lead-Lag Controller LL357D4 Lead/Lag controller with thermostat and sub-base. [Add $950.00]
S/04581 Lead-Lag Controller CommStat 3TM Lead/Lag Controller - solid state controller designed to operate a fully or partially redundant air conditioning system. Lead/ lag changeover is factory set at 7 days, but is field programmable in 1/2 day increments from 1/2 to 7 days. The Co [Add $950.00]
S/01190 Lead-Lag Adapter Heat pump adaptor for the CommStat 3™ lead/lag controller [Add $1110.00]
80515 Lead-Lag Controller CommStat 4TM Lead/Lag Controller - Solid state controller designed to control up to 4 fully or partially redundant HVAC units. It has outputs for remote alarms, as well as user selectable economizer and generator run strategy. DC power back up. See CommSt [Add $1250.00]
S/09481 Lead-Lag Controller CoolLinks Comprehensive PLC, Lead Lag Controller Integrated HVAC and Remote Monitoring Solution includes inside sensor, outside temperature and humidity sensor with mounting kit, relay alarm enhancement for smoke, hydrogen and generator options, prewired [Add $7021.00]
80503 Lead-Lag Remote Sensor can be used with either the CommStat 3TM lead/lag controller or the CommStat 4TM lead/lag controller. [Add $28.00]
80515 CommStat 4TM Expansion Cable A cable that links one CommStat 4TM Controller to another CommStat 4TM Controlle [Add $13.00]
70614 Energy Monitoring System MAR7000 controller is a stand-alone self-programming energy monitoring system. It works with single and two stage air conditioners and heat pumps. It has built in temperature, humidity, and motion detection. It can be set to work as an independent cont [Add $1348.00]
70616 Energy Monitoring System (w/ CO2) MAR7000 controller is a stand-alone self-programming energy monitoring system. It works with single and two stage air conditioners and heat pumps. It has built in temperature, humidity, and motion detection, and CO2 sensor. It can be set to work as an [Add $2059.00]
Supply Air Register
N/A - No supply air register required [Add $0.00]
80676Supply Grille 30" x 10" Adjustable, aluminum, double deflection supply grille [Add $116.00]
Return Air Grille
N/A - No return air grille [Add $0.00]
80679Return Grille 30" x 16" Aluminum return grille [Add $99.00]
80673Return Filter Grille 30" x 16" Aluminum return filter grille. Not recommended for economizing units. Filter used in Return Filter Grille is 1” (25 mm) thick. [Add $155.00]
Labor Warranty
N/A - No labor warranty required [Add $0.00]
Silver ServiceWarranty Silver Service - 1st year parts and labor. [Add $570.00]
Gold ServiceWarranty Gold Service - 2 years parts and labor. [Add $925.00]

Specialty Options

Explosion Proof
N/A Explosion Proof not required
Explosion Proof Explosion Proof required

#3J11
1/8/14
Marvair AVHA60HPD000C
Standard Features
  • R-410A Green Refrigerant
  • Scroll Compressor
  • Lanced fins on evaporator and condenser coils.
  • High and low pressure switch with lockout protection
  • Phase Monitor
  • Adjustable time delay relay
  • Dry contacts for remote alarms
  • Service access valves
  • 1" filter
  • Front Control Panel allows easy access and complies with NEC clearance codes on redundant side-by-side systems.
  • LEDs indicate operational status and fault conditions
  • Foil backed insulation on the indoor air path
  • Copper tube, aluminum fin evaporator & condenser coils.
  • Sloped top with flashing
  • Built-in mounting flanges
  • Single Point Power Entry
  • ECM Blower Motors
  • 1000-Hour Salt Spray, Baked On Polyester Finish
  • Built In Circuit Breakers With Lockable Outside Access Door (Disconnect On 460 Volt Models)
  • Barometric Damper with Washable Outside Air Filter
Options
Accessories
1.00